VALIDAÇÃO DO INSTRUMENTO DE CUIDADO DO ENFERMEIRO AO PACIENTE CRÍTICO COM CATETER VENOSO CENTRAL

Arquivos de Ciências da Saúde da Unipar

Endereço:
Praça Mascarenha de Moraes, 4282 - UNIPAR - Zona III
Umuarama / PR
87502210
Site: https://ojs.revistasunipar.com.br/index.php/saude
Telefone: (44) 3621-2816
ISSN: 1982-114X
Editor Chefe: Giuliana Zardeto
Início Publicação: 31/01/1997
Periodicidade: Quadrimestral
Área de Estudo: Ciências da Saúde

VALIDAÇÃO DO INSTRUMENTO DE CUIDADO DO ENFERMEIRO AO PACIENTE CRÍTICO COM CATETER VENOSO CENTRAL

Ano: 2022 | Volume: 26 | Número: 3
Autores: JESUS, S. C. de.; BERTONCELLO, K. C. G.; GONÇALVES, F. A. F.; COLAÇO, A. D.; COSTA D. G. da.
Autor Correspondente: COSTA D. G. da. | [email protected]

Palavras-chave: Estudos de validação, Confiabilidade e validade, Cuidados de enfermagem, Unidades de terapia intensiva, Validation studies, Reliability and validity, Nursing care, Intensive care units, Estudios de validación, Fiabilidad y validez, Cuidados de enfermería,

Resumos Cadastrados

Resumo Português:

Objetivo: Validar o conteúdo do instrumento de cuidado do enfermeiro ao paciente com cateter venoso central, internado na unidade de terapia intensiva. Métodos: Estudo quantitativo, conduzido em duas etapas: análise teórica por sete enfermeiros especialistas, dos itens do instrumento construído anteriormente e análise estatística a partir do Índice de Validade de Conteúdo e o coeficiente Alpha de Cronbach. Resultados: Após avaliação dos especialistas, o instrumento compôs-se por 36 itens e quatro domínios. Todos os itens apresentaram índice de validade de conteúdo superior a 0,78, com concordância de 0,85 a 1,00 nas avaliações. O índice de validade de conteúdo médio dos domínios e do instrumento foi maior que 0,90. Os itens dos domínios apresentaram consistência interna satisfatória. Conclusão: O instrumento de cuidado do enfermeiro apresentou conteúdo validado e confiável, sendo, portanto, seguro e de qualidade para cuidados com o paciente crítico com cateter venoso central.



Resumo Inglês:

Objective: To validate the content of the nurse's care instrument for patient with a central venous catheter in the intensive care unit. Methods: Quantitative study, conducted in two stages: theoretical analysis by seven specialist nurses of the instrument items previously developed and statistical analysis based on the Content Validity Index and Cronbach's Alpha coefficient. Results: After expert evaluation, the instrument consisted of 36 items and four domains. All items had a content validity index greater than 0.78, with an agreement between 0.85 and 1.00 in the evaluations. The mean content validity index of the domains and the instrument was greater than 0.90. The domain items showed satisfactory internal consistency. Conclusion: The nurse's care instrument presented validated and reliable content, being, therefore, safe and of quality for the care of critically ill patients with central venous catheters.



Resumo Espanhol:

Objetivo: Validar el contenido del instrumento de atención de la enfermera al paciente con catéter venoso central, ingresado en la unidad de cuidados intensivos. Métodos: Estudio cuantitativo, conducido en dos etapas: análisis teórico por parte de siete enfermeros especialistas, de los ítems del instrumento construido anteriormente y análisis estadístico a partir del Índice de Validez de Conteúdo y el coeficiente Alpha de Cronbach. Resultados: Tras la evaluación de los expertos, el instrumento quedó compuesto por 36 ítems y cuatro dominios. Todos los ítems tuvieron un índice de validez de contenido superior a 0,78, con un acuerdo entre 0,85 y 1,00 en las evaluaciones. El índice medio de validez de contenido de los dominios y del instrumento fue superior a 0,90. Los ítems de los dominios mostraron una consistencia interna satisfactoria. Conclusión: El instrumento de cuidado del enfermero presentó un contenido validado y fiable, siendo, además, seguro y de calidad para el cuidado del paciente crítico con catéter venoso central.