PROJETO DE ANÁLISE DAS INSTALAÇÕES DE UMA GRANJA DE CRIAÇÃO DE SUÍNOS

Revista Brasileira de Contabilidade e Gestão

Endereço:
Rua Dr. Getúlio Vargas - Universidade - Bela Vista
Ibirama / SC
89140000
Site: https://www.revistas.udesc.br/index.php/reavi/index
Telefone: (47) 9921-0350
ISSN: 2764-7471
Editor Chefe: Caroline Sulzbach Pletsch
Início Publicação: 09/08/2012
Periodicidade: Semestral

PROJETO DE ANÁLISE DAS INSTALAÇÕES DE UMA GRANJA DE CRIAÇÃO DE SUÍNOS

Ano: 2015 | Volume: 4 | Número: 8
Autores: Luana Loch, Jonathan David Abreu, Beatriz Day, Cristiane Gracieli Kloth, Adrieny Taliny Comper
Autor Correspondente: Cristiane Gracieli Kloth | [email protected]

Palavras-chave: suinocultura, tratamento de efluentes, reutilização de efluentes, pig farming, swine-breeding, wastewater treatment, reuse of effluents

Resumos Cadastrados

Resumo Português:

A produção de alimentos e a sua preocupação com o meio ambiente no processo e desenvolvimento tecnológico mensuram sobre a necessidade de minimizar o impacto que a produção de efluentes provenientes da suinocultura gera comparativamente ao efluente sanitário humano. O presente estudo analisou as instalações de uma granja de criação de suínos e realizou análises físico-químicas e microbiológicas do efluente proveniente dos dejetos dos suínos. A contagem dos coliformes termotolerantes foi realizada após 24 horas de incubação. A contagem evidenciou a presença de coliformes, o que resultou em um valor de 241960 NMP/100 mL. Para a determinação dos valores de nitrogênio total foram empregadas amostras diluídas de 1:10 devido a pequena faixa de detecção do aparelho. Desta forma o nitrogênio de entrada resultou em valores de leitura de 11,5 mg/L, e no ponto de saída obteve-se o valor de 4,2 mg/L. De acordo com os ensaios realizados, o tratamento do efluente da propriedade está em conformidade com a resolução Conama 357/2005 com redução efetiva de coliformes, DBO, concentração de nitrogênio e fósforo.



Resumo Inglês:

Food production and concern on the environment in the technological process and development have an important role to minimize the impact caused by the production of effluents from pig breeding, comparatively to human sanitary effluents. The installations of a pig farm were investigated and physical-chemical and micro-biological analyses of the effluent were undertaken. Thermo-tolerant coliform counts were performed after 24 hours of incubation. Counting detected coliforms at a rate of 241960 NMP/100 mL. Diluted samples 1:10 were employed to determine total nitrogen rates, due to the small detection band of the apparatus. Entry nitrogen was 11.5 mg/L while it amounted to 4.2 mg/L at exit. According to assays undertaken, the treatment of the effluent on the farm complies with Resolution by Conama 357/2005 with an effective decrease in coliforms, BOD, and N and P concentrations.



Resumo Espanhol:

La producción de alimentos y su preocupación por el medio ambiente en el proceso y desarrollo tecnológico, miden la necesidad de minimizar el impacto que genera la producción de efluentes derivados de la porcicultura frente a los efluentes sanitarios humanos. El presente estudio analizó las instalaciones de una granja porcina y realizó análisis físico-químicos y microbiológicos del efluente de los desechos porcinos. El recuento de coliformes termotolerantes se realizó a las 24 horas de incubación. El conteo mostró la presencia de coliformes, lo que resultó en un valor de 241960 MPN/100 mL. Para la determinación de los valores de nitrógeno total se utilizaron muestras diluidas 1:10 debido al pequeño rango de detección del dispositivo. De esta forma, el nitrógeno de entrada dio como resultado valores de lectura de 11,5 mg/L, y en el punto de salida se obtuvo un valor de 4,2 mg/L. De acuerdo con las pruebas realizadas, el tratamiento de los efluentes de la propiedad cumple con la Resolución Conama 357/2005 con reducción efectiva de coliformes, DBO, concentración de nitrógeno y fósforo.